Specifications

Connection Inlet Flange DN 250 CF (13.25")
Connection Outlet Flange DN 40 ISO-KF (NW40)
Cooling Method Water Cooling
Power Supply Voltage DC > 50V
Pumping Speed Air Nitrogen 1.38

TURBOVAC 1450 iR DN 250 CF IND

Part Number: 850142A00

Contact us for availability

Click For Availability

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Variant TMP
850122A00 TURBOVAC iR IND - Industrial version - remote operation, radiation robust
850142A00

TURBOVAC i/iX

TURBOVAC i is a well-proven turbomolecular pump platform ranging from 90 to 1450 l/s. TURBOVAC i comes with the latest hybrid bearing design offering a permanent magnet upper bearing paired with an oil-free lower mechanical bearing offering the cleanest high vacuum conditions.

 

With TURBOVAC i we offer variants covering UHV (Ultra High Vacuum), throughput IND (Industrial) as well as iR (radiation robust) variants with remote electronics. TURBOVAC i pumps are available with a compact interface offering the control of up to two accessories, basic RS485, USB and DIGITAL I/O control. The TURBOVAC i series also offers the full spectrum of field bus support. The universal connection called "Anybus" enables communication via Profibus, Ethernet IP, ProfiNET as well as EtherCAT through selectable modules.

 

TURBOVAC iX also offers the Anybus interface, the ability to control your fore vacuum pump, and up to 6 accessories, a gauge interface turning the pump into a full vacuum control solution. Along with single inlet pumps, we offer a wealth of multi-inlet, cartridge pumps, and customized products via our Customer Focused Engineering team - please come and talk to our sales teams.

 

TURBOVAC i pumps, in general, come stand-alone - the suitable power supply unit, comms/power cables, and cooling options need to be ordered separately. TURBOVAC 1350, 1450 and the 850, 950 IND variants always come already equipped with a water cooling block.

TURBOVAC 1450 iR

The TURBOVAC iR turbomolecular vacuum pump range has been developed to fulfil the requirements of demanding applications where high ionizing radiation is surrounding while providing the needed vacuum. Thanks to this exceptional tolerance against radiation the performance of the TURBOVAC iR pump is assured... and so is the operation of your application. With TURBOVAC iR you get the right solution for all kinds of remote operation.

Features and Benefits

  • Radiation resistance up to 1 MGray - Thanks to this exceptional tolerance against radiation the performance of the TURBOVAC iR pump is assured... and so is the operation of your application.
  • Remote operation - With TURBOVAC iR you get the right solution for all kinds of remote operations. The controller TURBO.DRIVE 500e can drive any of the TURBOVAC iR family members on distances of up to 1000 m, and this with minimal performance losses.
  • Long service lifetime - The TURBOVAC iR pumps offer a long service lifetime: you can count on a maintenance-free period from 4 and up to 5 years.
  • TURBO.DRIVE 500e - A powerful and compact solution to operate the TURBOVAC iR series products at any required distance. Besides driving the pump, the TURBO.DRIVE 500e controller can also independently control two standard accessories such as cooling fans or valves. Drive remote electronics with on/off function and status LEDs, LEYASSIST software option via USB port.

General Product Information

Accessories / Scope of Supply TURBOVAC i pumps come stand-alone - the suitable power supply unit, comms/power cables, and cooling options need to be ordered separately. IND industrial variants come with an equipped water cooling unit and are water cooling only.
Connection Outlet Flange DN 40 ISO-KF (NW40)
Connection Inlet Flange DN 250 CF (13.25")
Cooling Method Water Cooling
Power Supply Frequency DC Voltage
Power Supply Voltage DC > 50V
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 250 CF (13.25") | DN 40 ISO-KF (NW40)
Certification of Product CE
RoHS
REACH
China RoHs - China Material Content Declaration
CSA (C22.2 No.61010-1-12)
UL (61010-1 3rd Edition)

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Storage Max 70.00
Temperature Ambient Operation Min 5.00
Temperature Ambient Storage Min -15.00

Classification

Classification Dry or Wet Pump Dry
Classification Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Classification High / Medium / Rough Vacuum pump High Vacuum Pump
Classification Vacuum Pump Technology Turbomolecular Pump - hybrid bearing oil free

Performance Data

Compression Ratio Air Nitrogen 1.000 × 10⁸
Compression Ratio Helium 4.000 × 10⁵
Compression Ratio Hydrogen 20000.00
Pumping Speed Air Nitrogen 1.38
Gas Throughput Air Nitrogen Max 1.60
Gas Throughput Helium Max 1.20
Gas Throughput Max Hydrogen 1.00
Gas Throughput Argon Max 1.25
Compression Ratio Argon 1.000 × 10⁸

Connectivity - Communication Interface

Communication Interface Protocol none - no comms interface on pump itself

Operation Conditions - Limitations

Flow Cooling Water Min 1.667 × 10⁻⁵
Flow Cooling Water Max 3.000 × 10⁻⁵
Pressure Permissible Supply Cooling Water - Min and Max 4.000 × 10⁵
4.000 × 10⁵